Description
The DEXUP Patient Warmer is a high-performance forced-air warming system designed to maintain and regulate patient body temperature during pre-operative, intra-operative, and post-operative care. It ensures accurate and consistent warming through precise temperature control and even heat distribution, helping reduce the risk of hypothermia and enhancing patient comfort.Designed with a compact, lightweight, and portable structure, the DEXUP Patient Warmer is suitable for use in operating rooms, ICUs, labour rooms, HDUs, and emergency care areas. Its advanced safety systems, HEPA air filtration, and user-friendly control panel make it a reliable solution for continuous clinical use.
Key Features:
- Precise temperature control with adjustable settings
- Uniform and even heat distribution
- High-speed heat circulation for quick warming
- Lightweight and portable design for easy manoeuvrability
- Advanced safety features with overheat protection and continuous monitoring
- Compatible with full body, upper body, and lower body warming blankets
- User-friendly and intuitive control panel
- HEPA air filtration for clean air delivery
- Durable and high-performance construction
- Easy cleaning and maintenance
- Trolley-compatible design for enhanced mobility
- Undisturbed airflow without affecting the surrounding environment
Key Specification & Dimensions:
| Parameter | Details |
|---|---|
| Dimensions (L × W × H) | 250 × 300 × 340 mm (excluding extrusions) |
| Weight | Approx. 5.5 kg |
| Air Flow Accuracy | ±10 m³/h |
| Air Flow Levels | Level 0: 15 m³/h, Level 1: 30 m³/h, Level 2: 45 m³/h, Level 3: 60 m³/h, Level 4: 70 m³/h, Level 5: 85 m³/h |
| Maximum Output Pressure | >2600 Pa |
| Temperature Range | 33°C to 43°C (0.5°C increments) |
| Temperature Accuracy | ±1.5°C |
| Modes of Operation | Ambient Mode, Warming Mode |
| Alarms | Overheat alarm, temperature control alarm, high temperature alarm, low temperature alarm, heater error alarm, fan error alarm, temperature sensor alarm |
| Power Supply | AC 220V, 50 Hz |
| Power Consumption | 1800 VA (Max.) |
| Safety Class | Class I, Type BF |
| Ingress Protection | IPX1 (anti-dripping sealing unit) |
| Operating Temperature | +10°C to +40°C |
| Operating Humidity | 30% to 75% |
| Atmospheric Pressure | 700 hPa to 1060 hPa |
| Components | Upper case, lower case, fan, air tube, filter, control panel, operation panel |
| Compatible Blankets | Full Body Blanket, Upper Body Blanket, Lower Body Blanket |